• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Wed, 01.05.24

Search results


May 2019
Hussein Sliman MD, Avinoam Shiran MD, Dallit Mannheim MD, Eyal Avraham MD, Ron Karmeli MD, Nader Khader MD, Barak Zafrir MD, Ronen Rubinshtein MD and Ronen Jaffe MD

Background: Access-site bleeding is a common complication of transfemoral transcatheter aortic valve implantation (TAVI). Percutaneous stent-graft implantation within the femoral artery may achieve hemostasis and avert the need for more invasive surgical vascular repair; however, failure to advance a guidewire antegradely via the injured vessel may preclude stent delivery. While retrograde stent-graft delivery from the distal vasculature may potentially enable percutaneous control of bleeding, this approach has not been reported.

Objectives: To assess the feasibility of a retrograde approach for stent-graft implantation in the treatment of access-site bleeding following transfemoral TAVI.

Methods: A prospective TAVI registry was analyzed. Of 349 patients who underwent TAVI, transfemoral access was used in 332 (95%). Access-site injury requiring stent-graft implantation occurred in 56 (17%). In four patients (7%), antegrade wiring across the site of vascular injury was not possible and a retrograde approach for stent delivery was used.

Results: Distal vascular access was achieved via the superficial femoral or profunda artery. Retrograde advancement of a polymer-coated 0.035” wire to the abdominal aorta, followed by stent-graft delivery to the common femoral artery, achieved hemostasis in all cases. During a median (interquartile range) follow-up period of 198 (618) days (range 46–2455) there were no deaths and no patient required additional vascular interventions.

Conclusions: A retrograde approach for stent-graft delivery is feasible and allows percutaneous treatment of a common femoral artery injury following TAVI in patients who are not suitable for the conventional antegrade approach.

January 2014
Daniel Silverberg, Violeta Glauber, Uri Rimon, Yakubovitch Dmitry, Emanuel- Ronny Reinitz, Basheer Sheick-Yousif, Boris Khaitovich, Jacob Schneiderman and Moshe Halak
Background: Surgery for complex aortic aneurysms (thoracoabdominal, juxtarenal and pseudoaneurysms) is associated with a high morbidity and mortality rate. Branched and fenestrated stent grafts constitute a new technology intended as an alternative treatment for this disease.

Objectives: To describe a single-center experience with fenestrated and branched endografts for the treatment of complex aortic aneurysms.

Methods: We reviewed all cases of complex aortic aneurysms treated with branched or fenestrated devices in our center. Data collected included device specifics, perioperative morbidity and mortality, re-intervention rates and mid-term results.

Results: Between 2007 and 2012 nine patients were treated with branched and fenestrated stent grafts. Mean age was 73 years. Mean aneurysm size was 63 mm. Perioperative mortality was 22% (2/9). During the follow-up, re-interventions were required in 3 patients (33%). Of 34 visceral artery branches 33 remained patent, resulting in a patency rate of 97%. Sac expansion was seen in a single patient due to a large endoleak. No late aneurysm- related deaths occurred.

Conclusions: Branched and fenestrated stent grafts are feasible and relatively safe alternatives for the treatment of complex aortic aneurysms involving the visceral segment. Further research is needed to determine the long-term durability of this new technology. 

September 2007
O. Galili, S. Fajer, Z. Eyal and R. Karmeli

Background: In recent years there has been an increase in endovascular repair of thoracic aortic aneurysms. In cases of insufficient neck length, occlusion of left subclavian artery achieves proper sealing and is usually well tolerated. Selected cases require revascularization of the left subclavian artery, including patients after coronary bypass surgery (left internal mammary to left anterior descending) and those with arm claudication or subclavian steal syndrome.

Objectives: To evaluate the tolerability of left subclavian artery occlusion by stent graft without revascularization.

Methods: Thirty patients with thoracic aortic aneurysms underwent endovascular repair between July 2000 and November 2004. Eleven of them had occlusion of the left subclavian artery that required revascularization in two. Follow-up (average 3 years) included a) blood pressure measurements of both arms at rest, after effort and pulse palpation, and b) vertebral blood flow by duplex scan.

Results: Of nine patients with no revascularization, 8 (89%) tolerated left subclavian artery occlusion with no claudication or steal syndrome; one (11%) suffered mild claudication only after effort and required no intervention. No left radial pulses were palpated in the nine patients. Blood pressure measurements in the left arm showed an average decrease of 40%, which remained constant after induced effort in all patients and was clinically insignificant. Duplex scan demonstrated reverse flow in the left vertebral artery in 8 of 9 patients (89%) and occlusion in 1 (originating in the arch and covered by the stent graft) with no clinical symptoms.

Conclusions: Left subclavian artery occlusion by stent graft is a tolerable procedure in the long term. In most cases, the constant decrease in blood pressure remained unchanged during follow-up and had no significant adverse affects. Most patients do not require revascularization prior to the endovascular procedure.
 

June 2004
E. Atar, G. Feldman, H. Neyman, E. Tzypin, A. Belenky and M. Katz
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel